(Click picture to see animation)
• Underwriters Laboratories
tested and listed per UL-2215
• Designed for no internal or confined space entry when performing routine
maintenance. (see note1 below)
• Kleerwater™ can handle larger influent flows, allowing
for smaller separator tanks. With smaller separation tanks, less installation
costs.
• Kleerwater™ separators utilizes Stokes Law for defining rates of
rise of oil spheres in a liquid medium
• Unique patented oil separation process enhances oil from water separation
efficiencies
• Separation efficiencies down to 5 ppm & lower. (see
note 2 below)
• Electronic audible and visual alarms available for preset level alarm
notifications
• Separator material of construction: carbon steel.
• Single or double wall steel configurations available
• Handle continuous or intermittent influent flow rates.
Kleerwater™ Gravity Oil Water Separators
Kleerwater™, oil water
separators, maybe constructed in single or double wall tank designs.
Double wall configurations have interstitial monitoring capabilities.
Tanks are built to Underwriters Laboratories UL-58 / UL-1746 construction
standards. Kleerwater™ oil water separators are listed and tested
to Underwriters Laboratories, UL-2215 standards. Separators are designed
to separate free-floating oils and greases with specific gravities
between 0.7 and 0.94, from fresh water influents.
Kleerwater™ separator design criteria is based on Stokes Law which defines
the rates of rise of oil spheres in a liquid medium. Special coalescer "balls"
enhances the separator's efficiency to obtain unmatched performance, down
to
5 ppm.
Kleerwater™ oil water separators can handle larger influent flows, therefore
allowing for smaller separators tank utilization. With smaller separation tanks,
less installation costs are incurred.
Kleerwater™ separators are available with electronic audible and visual
alarms for preset notification of liquid levels in the separator.
Kleerwater™ oil water separators are not designed for use in applications
where cleaning detergents are involved unless the detergents are supplied and
furnished by Kleerwater™ LLC technologies.
Solvents or highly dissolved solids, such as untreated sanitary sewers, should
not be introduced into Kleerwater™ separators. Kleerwater™ separators
will not separate chemical emulsions, dissolved hydrocarbons or volatile organic
hydrocarbons.
1 – Maximum 180 day maintenance inspection
schedule must be implemented for this claim to be applicable.
Follow published maintenance instructions as published by the
Kleerwater™ oil water separator manufacturer.
2 – Efficiencies are dependent on influent
flow rates, concentrations and specific gravity of oil. Any one
of these factors can affect the separators efficiencies of oil
and water separation.
Sensors
and Control Panels
Oil Water
Interface Sensors
Oil
Water Interface Sensors lengths over 96”
Annular
Space Liquid Sensors
Control
Panels (1 to 2 Channels)
Control
Panels (3 or More Channels)
Sensor Lengths Selection Guide
Engineering
Specification:
Kleerwater
(rtf)
General Notes: Kleerwater (pdf)
Separator Sizing: Kleerwater (pdf)
Brochure Literature: Kleerwater
|